: RNFL thickness (average and four quadrant) from six SD-OCTs (Spectral OCT/SLO OPKO/OTI, 3D-OCT 2000 Topcon, RS-3000 NIDEK, Cirrus HD-OCT Zeiss, RTVue-100 Optovue, and Spectralis Heidelberg) and one time-domain OCT (Stratus OCT Zeiss) was measured twice in 38 right eyes of 38 randomly chosen healthy volunteers by two masked operators. Used OPKO OCT SLO OCT Um zu verkaufen - DOTmed Angebotseintrag #2242519: 2009 OPKO/OTI spectral OCT / SLO multifunction unit good working condition, great cosmetic, fully tested included elevating stand, printer, console with flat monitor, user manual, cover price includes crating, we ship worldwide product description: The Spectral OCT SLO is a non-contact, high-resolution non-invasive.
Abstract
Background
The aim of this study was to compare the agreement between spectral domain optical coherence tomography (SD OCT) and time domain stratus OCT (TD OCT) in evaluating macular morphology alterations in wet age-related macular degeneration (AMD).
Methods
This retrospective study was performed on 77 eyes of 77 patients with primary or recurring subfoveal choroidal neovascularization secondary to AMD. All patients underwent OCT examination using Zeiss Stratus OCT 3 (Carl Zeiss Meditec Inc, Dublin, CA) and Opko OTI Spectral SLO/OCT (Ophthalmic Technologies Inc, Toronto, Canada). In all radial line scans, the presence of intraretinal edema (IRE), serous pigment epithelium detachment (sPED), neurosensory serous retinal detachment (NSRD), epiretinal membrane (EM), inner limiting membrane thickening (ILMT), and hard exudates (HE) were evaluated. The degree of matching was quantified by Kappa measure of agreement.
Results
The percentage distribution of TD OCT findings versus SD OCT findings was: IRE 36.3% versus 77.9%, sPED 57.1% versus 85.7%, NSRD 38.9% versus 53.2%, EM 10.5% versus 26.3%, ILMT 3.8% versus 32.4%, and HE 6.4% versus 54.5%. The agreement was as follows: sPED: kappa value 0.15; NSRD: kappa value 0.61; IRE: kappa value 0.18; EM: kappa value 0.41; ILMT: kappa value 0.02; HE: kappa value 0.06.
Conclusion
The agreement in the evaluation of macular lesions between the two techniques is poor and depends on the lesion considered. SD OCT allows better detection of the alterations typically related to choroidal neovascularization such as IRE, PED, ILM thickening, and HE. Consequently its use should be strongly considered in patients with wet AMD.
Introduction
Although fluorescein angiography remains fundamental in determining the presence of choroidal neovascularization (CNV), many recent studies include optical coherence tomography (OCT) to investigate the severity of exudative macular pathologies, to evaluate the possibility of retreatment, and to monitor the response to anti VEGF therapy during follow up.–
In recent years the development of high-speed detection techniques (such as spectral domain [SD] OCT) has led to a significant improvement in OCT imaging performance, providing more detailed information on intraretinal morphology with respect to the first generation time domain (TD) OCT.–
The aim of this study was to assess the agreement between SD OCT and TD OCT in evaluating the CNV-related alterations in wet age-related macular degeneration (AMD).
Materials and methods
This retrospective observational study was performed on 77 eyes of 77 patients (34 men, 43 women, mean age 74.3 ± 9.7 years) affected by wet AMD attending our department between June and December 2009. The research adhered to the tenets of the declaration of Helsinki. All patients signed a written consent to permit the use of the images for this study. In order to qualify for the study, the patients were required to have primary or recurring subfoveal CNV secondary to AMD. Exclusion criteria were other types of CNV and the coexistence of any other macular diseases.
All patients underwent OCT examination using two OCT devices: TD OCT (Stratus OCT 4.0.1, Carl Zeiss Meditec Inc, Dublin, CA) and SD OCT (OCT/SLO Opko/ OTI, Ophthalmic Technologies Inc, Toronto, Canada). TD OCT uses a near-infrared frequency light of 820 nm, with an axial resolution of 10 μm and speed of 400 A-scans/sec. The light source of the SD OCT/SLO OTI is a modified super luminescent diode at a wavelength of 840 nm. The axial resolution is 5 μm and the transverse is 16 μm. The speed is set at 28000 A-scan/sec; every B-scan is composed of 512 A-scans. The OCT is coupled to a scanning laser ophthalmoscope (SLO). A single experienced examiner performed the OCT examinations with a standard protocol for the two tools on the same day. Using the TD OCT and the SD OCT every eye in this study underwent the radial lines acquisition protocol after centering the scans on the fovea. If doubt about the presence or the nature of a lesion aroused, a single radial scan was used by the examiner to move the scan and investigate the lesion itself. The images were then recorded on the OCT computer and subsequently observed and analyzed using display intrinsic to TD OCT and SD OCT by two independent experienced examiners unaware of the purpose of the research who evaluated the presence of intraretinal edema (IRE), serous pigment epithelium detachment (PED), neurosensory serous retinal detachment (NSRD), epiretinal membrane (EM), inner limiting membrane thickening (ILMT), and hard exudate deposition (HE). Possible disagreement was resolved after discussion, so that investigators agreed on all the images.
IRE was defined as a diffuse or localized hyporeflective area inside the neuroretina. PED was characterized as a dome-shaped lesion of the retinal pigment epithelium layer. NSRD showed up as a hyporeflective area between the retinal pigment epithelium and all the superior retina layers, and EM was consistent with a high reflective line on the inner layer of the retina. ILMT was viewed as a high reflective band between the vitreous and the retinal layers. HE was revealed as high reflective round or oval intraretinal lesions.
The extent of the match between the two evaluations was quantified by the Kappa measure of agreement. The Chi-square was used to evaluate links between the parameters.
Results
The percentage of distribution is listed in Table 1. In particular, IRE was detected by TD OCT in 28 eyes (36.3%) and by SD OCT in 60 eyes (77.9%). PED was discovered by TD OCT in 44 eyes (57.1%) and by SD OCT in 66 eyes (85.7%). NSRD was shown by TD OCT in 30 eyes (38.9%) and by SD OCT in 41 eyes (53.2%). EM was evidenced by TD OCT in 8 eyes (10.5%) and by SD OCT in 20 eyes (26.3%). ILMT was visualized by TD OCT in 3 eyes (3.8%) and by SD OCT in 25 eyes (32.4%). HE was identified by TD OCT in 5 eyes (6.4%) and by SD OCT in 42 eyes (54.5%).
Table 1
TD OCT | SD OCT | |
---|---|---|
IRE | 36.3% | 77.9% |
sPED | 57.1% | 85.7% |
NSRD | 38.9% | 53.2% |
EM | 10.5% | 26.3% |
ILMT | 3.8% | 32.4% |
HE | 6.4% | 54.5% |
Abbreviations: TD OCT, time domain optical coherence tomography; SD OCT, spectral domain optical coherence tomography; IRE, intraretinal edema; sPED, serous pigment epithelium detachment; NSRD, neurosensory serous retinal detachment; EM, epiretinal membrane; ILMT, inner limiting membrane thickening; HE, hard exudates.
The agreement rate for each OCT feature is reported in Table 2. More specifically, the presence of PED: kappa value 0.15; presence of NSRD: kappa value 0.61; presence of IRE: kappa value 0.18; presence of EM: kappa value 0.41; presence of ILMT: kappa value 0.02; presence of HE: kappa value 0.06.
Table 2
Kappa measure of agreement between TD OCT and SD OCT
Kappa value | |
---|---|
IRE | 0.18 |
sPED | 0.15 |
NSRD | 0.61 |
EM | 0.41 |
ILMT | 0.02 |
HE | 0.06 |
Abbreviations: TD OCT, time domain optical coherence tomography; SD OCT, spectral domain optical coherence tomography; IRE, intraretinal edema; sPED, serous pigment epithelium detachment; NSRD, neurosensory serous retinal detachment; EM, epiretinal membrane; ILMT, inner limiting membrane thickening; HE, hard exudates.
Discussion
OCT has become increasingly useful in the diagnosis and the treatment of AMD. The recent advent of SD OCT has increased the hope to obtain a more reliable tool in an attempt to define the changes in CNV activity,– and, consequently, the possible retreatment. Also, OCT can provide quantitative and qualitative information regarding CNV-related features, and the introduction of SD technology has led to a remarkable improvement in lesion imaging due to improved definition of the scanned images.,–
The two generations of OCT, TD and SD, have been largely investigated in order to evaluate repeatability and reproducibility of the examinations in many macular diseases, but the varying patterns of exudation secondary to AMD make OCT examination difficult to compare when performed with the same or more instruments. In fact some authors compared TD and SD macular thickness measurements findings obtained in different sessions and questioned the repeatability of the results.– It has also been demonstrated by Giani et al that retinal thickness measurements obtained by various OCT devices such as Stratus and Cirrus (Carl Zeiss Meditech Inc), Spectralis (Heidelberg Engineering Inc, Heidelberg, Germany) and 3D-OCT-1000 (Topcon Corporation, Tokyo, Japan) are different due to the analysis algorithms used to set retinal inner and outer boundaries. Nevertheless, Eriksson et al recently suggested the use of software for manual correction of foveal position when using Cirrus SD OCT (Carl Zeiss Meditech Inc) to reduce the variability of the measurements.
As a consequence, we decided not to compare the macular thickness findings but to evaluate the presence/ absence of AMD-related typical lesions when investigated by different generations of OCT. So far, to our knowledge, only Sayanagi et al compared the ability to delineate patterns of CNV activity using Stratus OCT and four different SD OCT devices, concluding that all SD OCT were statistically superior to delineate IRE presence. Therefore, it is not surprising that our study found that IRE was undetected by TD OCT in 32 patients (41%). This is of great relevance as IRE is considered the key factor in treatment and retreatment decisions, and most of the authors assess the lesions persistent activity if intraretinal fluid is present.
No other studies investigated the relative sensitivity of TD and SD OCT in identifying the single lesions typically related to CNV presence, and overall our results reveal a poor agreement. Indeed, some concordance between the two instruments can be found only in the identification of NSRD (kappa value 0.61) and EM (kappa value 0.41), but concordance was poor in the evaluation of IRE, PED, ILMT, and HE, where kappa value was always less than 0.2. These results may hint that the smaller lesions are more clearly identified by SD OCT (Figure 1). In fact SD OCT, due to its improved resolution and scan acquisition, enables the smaller structures in all the retinal layers to be visualized, in particular the internal and external limiting membrane, the inner segment/outer segment of the photoreceptors, and in some cases the Bruch’s membrane.–
(A). Macular horizontal line scan by time domain (TD) OCT. (B) Macular horizontal line scan by spectral domain (SD) OCT. The comparison between the two OCT tools points out that hard exudates (white arrow) are visualized only by the SD device, where also intraretinal fluid cysts appear more evident and numerous.
Abbreviation: OCT, optical coherence tomography.
A good match between the two tools has been registered only with respect to NSRD, probably because the fluid between the retinal pigment epithelium and the neuroretina is clearly serous and hyporeflective, and consequently can be easily detectable by both techniques. The moderate and slight agreement in detecting EM and ILM thickening, respectively, suggests that SD OCT more reliably detects these alterations, because of more sensitivity in visualizing the vitreomacular interface alterations, as already highlighted by some authors.–
This aspect could lead to better interpret the specific role of vitreomacular adhesions in the development of CNV, which has been postulated to have an active role by some authors but, more recently not by others. Our findings, that evidenced 26% to 32% of eyes presenting with EM or ILM, respectively, at SD OCT, overall resemble the data reported by Mojana et al that included a series of 170 eyes of which 27.8% had vitreomacular adhesion. In that study some patients underwent macular peeling and they concluded that tractional forces may antagonize the effect of anti-VEGF treatment, and cause pharmacological resistance in a subpopulation of patients. Consequently we think the possibility of detecting initial thickening of vitreoretinal interface could also have some prognostic relevance.
A surprising assumption of our study is that hard exudates were visible in 54.5% of eyes when investigated by SD OCT versus only 6.4% by TD OCT. This great difference is evidently due to the greater sensitivity of SD technology, but could also lead to misdiagnosis as hyperreflective points could correspond to retinal vessels or punctate hemorrhages not visible by TD OCT. Tomographic characteristics must assist the clinician in proper diagnosis; this could prove difficult in some circumstances such as the interpretation of small pseudocysts that can masquerade as outer retina tubulation caused by photoreceptors arrangement during late stages of exudative AMD. It appears evident that better diagnostic capabilities allowed by SD OCT require better operator abilities, as the detection of fine morphological aspects expand the spectrum of the corresponding retinal details identification.
Conclusion
In conclusion, our findings suggest that SD OCT can better disclose a large number of retinal lesions of various types, indicating a clear advantage in the detection of tiny abnormalities of the retinal morphology.
The agreement in the evaluation of macular lesions between the two techniques is poor and depends on the lesion considered. SD OCT allows better detection of the alterations typically related to CNV such as IRE, PED, ILM thickening, and HE. Consequently its use should be strongly considered in patients with wet AMD.
Footnotes
Disclosure
The authors report no conflicts of interest in this work.
References
Opko Spectral Oct Slo User Manual Online
Opko Spectral Oct Slo User Manual Download
Opko Spectral Oct Slo User Manual Youtube
'We are pleased to receive 510(k) clearance for the OPKO Spectral OCT SLO Combination Imaging System,” said Jane H. Hsiao, Ph.D., Vice Chairman and Chief Technical Officer of OPKO Health, and President of OPKO Instrumentation. “We believe that the high image quality produced by our Spectral OCT SLO and its versatile user-friendly interface offer the clinician a valuable tool for the detection and visualization of ocular pathologies. In addition, we recently hosted a FDA audit at our facility in Toronto, Canada where we manufacture our Spectral OCT SLO and ultrasound products and are pleased to announce it was accepted without any citation of deficiency after the inspection.”
About the Spectral OCT SLO
The Spectral OCT SLO is a non-contact, high-resolution non-invasive tomographic and confocal imaging device indicated for in vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of posterior ocular structures including: retina, macula, retina nerve fiber layer and optic disk. It is used as a diagnostic device to aid in the detection and management of ocular diseases affecting the posterior segment of the eye. In addition, the system can image the cornea, sclera and conjunctiva by changing the focal position.
About OPKO Health, Inc.
Miami-based OPKO is a specialty healthcare company engaged in the development, marketing, and sales of novel agents and both diagnostic and therapeutic devices for the management of ophthalmic diseases. For more information visit the company's website at www.opko.com.
This press release contains 'forward-looking statements,' as that term is defined under the Private Securities Litigation Reform Act of 1995 (PSLRA), which statements may be identified by words such as 'expects,' 'plans,' 'projects,' 'will,' 'may,' 'anticipates,' 'believes,' 'should,' 'intends,' 'estimates,' and other words of similar meaning, including statements regarding our product development efforts, our ability to commence sales of the Spectral OCT SLO in the United States, and our ability to develop a preclinical pipeline of novel agents for ophthalmic diseases, as well as other non-historical statements about our expectations, beliefs or intentions regarding our business, technologies and products, financial condition, strategies or prospects. Many factors could cause our actual activities or results to differ materially from the activities and results anticipated in forward-looking statements. These factors include those described in our filings with the Securities and Exchange Commission, as well as risks inherent in funding, developing and obtaining regulatory approvals of new, commercially-viable and competitive products and treatments. In addition, forward-looking statements may also be adversely affected by general market factors, competitive product development, product availability, federal and state regulations and legislation, the regulatory process for new products and indications, manufacturing issues that may arise, patent positions and litigation, among other factors. The forward-looking statements contained in this press release speak only as of the date the statements were made, and we do not undertake any obligation to update forward-looking statements. We intend that all forward-looking statements be subject to the safe-harbor provisions of the PSLRA.