Sokkia Sdl30 Digital Level User Manual

Sokkia Sdl30 Digital Level User Manual

Sokkia Set530r Operator's Manual

The “PowerLevel” makes measurement quick, easy and accurate

Sokkia Sdl30 Digital Level Manual

Service manual; Sokkia CX-101 Service Manual. Select either “User’1” or “User’2” as the softkey array to be registered. Page 274: Restoring Default Settings. This equipment has been tested and found to comply with the limits for a Class A digital. View & download of more than 51 Sokkia PDF user manuals, service manuals, operating guides. Measuring instruments user manuals, operating guides & specifications.

The SDL30 digital level makes quick work of measuring height and distance in all types of environments—from low light to bright sunlight and artificial light. It provides unwavering accuracy in the field even in adverse environments such as tunnels, heat shimmer, and vibration. Its large internal memory, digital display, and simple operation ensure fast and accurate measurements.

Sokkia

Key SLD30 features include:

  • High accuracy under adverse lighting and environments
  • Four measurement modes: single-fine, repeat-fine, average and tracking
  • Water and shock resistant
  • 2000-point internal memory
  • Li-ion power system for up to 8.5 hours of continuous operation

Sokkia Sdl30 Digital Level User Manual Free

Brief Specs

Sokkia
Height Accuracy (Electronic)1mm (With Fiberglass RAB-Code Staves)
Standard deviation for 1km double run leveling
Distance Accuracy (Electronic)[<10m = +/-10mm] [10m to 50m = +/-.1%xD] [>50m = .2%xD]
Display resolution (Height).0001 / .001m
Measuring Range1.6 to 100m
Magnification32x
CompensatorPendulum compensator with magnetic damping system
Data Storage2000 points
CommunicationsRS-232C
Dust/Water ProtectionIPX4
Operating Temperature-20 to +50ºC (-4 to +122ºF)
Operating TimeMore than 8.5 hours
SizeW158 x D257 x H182mm (W6.2 x D10.1 x H7.2in)
Weight2.4kg (5.3lb)

Sokkia Sdl30 Digital Level

Full specifications in brochure.